Photon
Portable gas analyzer using IR sensors. |
|
|
|
|
|
|
|
|
| NDIR sensors |
| Parameter |
Indication ranges |
Resolution |
Detection limit |
Accuracy |
Response time (t90) |
CO - carbon monoxide
NO - nitrogen oxides
NO2 - nitrogen dioxide
N2O - nitrous oxide
SO2 - sulphur dioxide |
min. range: 0…2000 ppm1 ppm |
1 ppm |
1 ppm |
±3 ppm abs.,or 3 % rel. |
45 s |
| max. range:0…100 %0.1 % |
0.1 % |
0.1 % |
±0.3 % abs.,or 3 % rel. |
45 s |
CO2 - carbon dioxide
CH4 - Methane |
min. range:0…5 %0.01 % |
0.01 % |
0.01 % |
±0.03 % abs.,or 3 % rel. |
45 s |
| max. range:0…100 %0.1 % |
0.1 % |
0.1 % |
±0.3 % abs.,or 3 % rel. |
45 s |
|
| Electrochemical sensors |
| Parameter |
Indication range |
Resolution |
Detection limit |
Accuracy |
Response time (t90) |
| O2 - oxygen |
0...25 % |
0.01 % |
0.01 % |
±0.2 % abs.,or 2 % rel. |
45 s |
| H2S - Hydrogen sulphide |
0...5000 ppm |
1 ppm |
1 ppm |
±3 ppm abs.,or 3 % rel. |
45 s |
| H2 - Hydrogen |
0...1000 ppm |
1 ppm |
1 ppm |
±3 ppm abs.,or 3 % rel. |
45 s |
|
| Other sensors |
| Parameter |
Method |
Indication range |
Resolution |
Detection limit |
Accuracy |
Response time (t90) |
| O2 - oxygen |
Partial press. sensor |
0...100 % |
0.1 % |
0.1 % |
±0.2 % abs.,or 2 % rel. |
45 s |
|
| Temperature measurements |
| Parameter |
Method |
Indication range |
Resolution |
Detection limit |
Accuracy |
Response time (t90) |
| Tgas - flue gas temperature |
Thermocouple |
-10..1000 °C |
1 °C |
1 °C |
±2 °C abs.,or 1.5 % rel. |
30 s |
| Tamb - ambient temperature |
Thermistor |
-10..100 °C |
1 °C |
1 °C |
±1 °C abs.,or 1.5 % rel. |
30 s |
|
| Other measured values |
| Parameter |
Method |
Indication range |
Resolution |
Detection limit |
Accuracy |
Response time (t90) |
| Pressure |
DMS bridge |
-20...+20 hPa |
0.1 Pa |
0.1 Pa |
±2 Pa abs., or 5 % rel. |
10 s |
| Diff. Pressure |
DMS bridge |
-20...+20 hPa |
0.1 Pa |
0.1 Pa |
±2 Pa abs., or 5 % rel. |
10 s |
| Ambient pressure |
DMS bridge |
800...1200 hPa |
0.1 hPa |
0.1 hPa |
±0.5 hPa abs., or 5 % rel. |
10 s |
|
| Calculated parameters |
| Parameter |
Method |
Indication range |
Resolution |
Detection limit |
Accuracy |
Response time (t90) |
| Lambda - excess air number |
calculated |
1...10 |
0.01 |
0.01 |
0.01 |
5 s |
| qA - combustion losses |
calculated |
0...100 % |
0.1 % |
0.1 % |
0.1 % |
5 s |
| Eta - efficiency |
calculated |
0...100 % |
0.1 % |
0.1 % |
0.1 % |
5 s |
|
A |