| Portable combustion analyzer using electrochemical and IR gas sensors. |
|
 |
|
|
The combustion analyzer GA-40Tplus is designed especially for service technicians who are permanently employed in measuring emissions and carrying out adjustments as well as making long-term measurements and inspections on various burner and heating equipment. For this purpose the analyzer is fitted with a high-powered dryer and heated hose. The analyzer can be equipped with up to 9 sensors (7 electrochemical and 2 IR sensors).
All parts of the combustion analyzer are designed for long and trouble-free operation. 6 additional analog inputs for voltage/current signals and temperature together with 2 optional analog outputs give the instrument an unheard of flexibility. The analyzer can also be fitted with two IR sensors for direct measurement of CO2 and CH4.
|
|
|
|
|
|
|
| Standard configuration |
- Measurement of gas concentrations
- Gas concentrations measured with NDIR sensors: CO2, CH4
- Gas concentrations measured with electrochemical sensors: O2
- Toxic gas concentrations measured with electrochemical sensors: CO, NO, NO2, SO2, H2S,, H2. Please ask for quote for other gases.
- Measurement of other parameters
- Measurement of gas and ambient temperatures
- Pressure, draft and differential pressure measurements with 1 Pa resolution
- Soot test according to Bacharach with a pump flow of 1.62 l/min
- Flow velocity (Option)
- 6 analog inputs (2 current/voltage, 2 thermocouple, 2 thermistor)
- Calculation
- CO2 concentration
- Calculation of absolute and relative mass concentrations & relative emissions
- Calculation of all relevant combustion parameters
- Processing and presentation of measured data
- All results shown on display
- Averaging of all measured values. Averaging time: 10 sec - 60min
- Graphical presentation of all measured values as diagram
- Memory capacity for 1024 sets of data, organised into 10 data banks
- Up to 9 separate items in a data set
- User definition of the 9 items
- Memory capacity for 30 reports
- Data logger function for the analog inputs
- All measured values, stored values or displays can be printed on the internal printer
- Powerful PC program for analyser settings and data communication
- Software-Eigenschaften
- International compatibility (language, date format etc.)
- Password protection for settings
- Automatic zeroing when the analyser is switched on
- Calibration of O2/CO2 during use
- All parameters programmable
- List of 22 common fuels
- 10 further freely programmable fuels
- Permanent automatic check of the instruemnt with acoustic warning and full information in the "control list"
- Compensation of cross sensitivity and temperature drift of gas sensors
- Hardware capabilities
- Electronic regulation of the pump flow rate
- Integrated clock/calendar
- Internal 57 mm dot-matrix printer
- Power from rechargeable battery or mains
- Big (70 x 60 mm) LCD display with backlighting (Graphics or 11 x 21 characters)
- Gas probe with thermocouple and condensate trap
- Power for heated probe holder during mains operation
- RS-232C interface and multifunctional PC program
|
|
|
| Optional accessories |
- External ambient temperature sensor
|
|
|
| Technical data |
- Size of case W x H x D: 19’’ x 11.5’’ x 8’’
- Weight w/o probe: 25 lbs
- Display size: Graphical - LCD, with backlighting and variable contrast, 128x112pixels, 3" x 2,5"
- Printer: high-speed dot matrix printer with graphics capability for 2.25" normal paper
- Data memory: Memory for 30 reports and 10 banks containg a total of 1024 sets of data
- CO - measurement channel: Separate from the other gas channels. If the freely programmable maximum is exceeded then the sensor is purged with air, without interrupting the other measurements
- Interface: RS232C
- Power supply: 110/230 VAC 50 ÷ 60 Hz
- Charging time: Lead-acid battery 12V / 2.2 Ah, charging time 10 h, working time approx. 6 h (w/o dryer))
- Gas pump: Membrane pump, electronically regulated at 1.5 lpm
- Probe: Inconel stainless steel probe with pistol grip. Heated for soot test
- Probe length: 12" (other options available)
- Length of heated line: 10 ft.
- Peltier dryer
- Gas filter: In line filter 20 µm
- Operating temperature: 10°C ÷ 50°C
- Storage temperature: -20°C ÷ +55°C
|
|
|
|
|
|
|
|
|
|
|
|
A |