| Parameter |
Measuring method |
Range |
Resolution |
Accuracy |
Detection
Limit |
Time (T90) |
| Gases measured in standard configuration |
O2 - oxygen,
volumetric concentration |
electrochemical gas sensor |
0..25 % |
0.01 % |
± 0.2 %
or 2 % rel. |
0.01 % |
45 s |
CO2 - carbon dioxide,
volumetric concentration |
calculated from volumetric concentration of O2 |
0..25 % |
0.01 % |
± 0.2 %
or 2 % rel. |
0.01 % |
45 s |
CO - ambient carbon monoxide,
volumetric concentration |
electrochemical gas sensor |
0..100 ppm |
0.1 ppm |
± 0.5 ppm
or 5 % rel. |
0.1 ppm |
45 s |
CO - carbon monoxide,
volumetric concentration |
electrochemical gas sensor |
0..20000 ppm |
0.1 or 1 ppm
set by user |
± 5 ppm
or 5 % rel. |
0.1 ppm |
45 s |
CO - carbon monoxide,
volumetric concentration |
electrochemical gas sensor |
0..20,0000 ppm |
1 ppm |
± 5 ppm
or 5 % rel. |
1 ppm |
45 s |
COmg - carbon monoxide,
mass concentration |
calculated from volumetric concentration of CO |
0... |
1 mg/Nm3 |
± 5 mg/Nm3
or 5 % rel. |
1 mg/Nm3 |
45 s |
COrel - carbon monoxide,
mass concentration relative to O2 |
calculated from volumetric concentration of CO and O2 |
0... |
1 mg/Nm3 |
± 5 mg/Nm3
or 5 % rel. |
1 mg/Nm3 |
45 s |
| Gas measured with optional electrochemical sensor |
NO - nitric oxide,
volumetric concentration |
electrochemical gas sensor |
0..1000 ppm |
0.1 or 1 ppm
set by user |
± 5 ppm or
5 % rel. |
1 ppm |
45 s |
NOxmg - nitric oxide
mass concentration |
calculated from volumetric concentration of NO |
0... |
2 mg/Nm3 |
± 10 mg/Nm3
or 5 % rel. |
2 mg/Nm3 |
45 s |
NOxrel - nitric oxide
mass concentration |
calculated from volumetric concentration of NO and O2 |
0... |
2 mg/Nm3 |
± 10 mg/Nm3
or 5 % rel. |
2 mg/Nm3 |
45 s |
| Temperature measurements |
| Tgas - flue gas temperature |
Thermocouple |
-10..1000°C |
0.1 or 1°C
set by user |
± 2°C
or 1.5 % rel. |
1°C |
30 s |
| Tamb - ambient temperature |
Thermistor |
-10..100°C |
0.1 or 1°C
set by user |
± 1°C |
1°C |
30 s |
| Calculated parameters |
| TI (CO/CO2-Toxic Index) |
calculated |
0...0.01 |
0.0001 |
0.0001 |
|
|
| Lambda - excess air number |
calculated |
1..10 |
0.01 |
0.01 |
|
|
| qA - combustion losses |
calculated |
0..100 % |
0.1 % |
0.1 % |
|
|
| Eta - efficiency |
calculated |
0..120 % |
0.1 % |
0.1 % |
|
|
| Other measured values |
| Pressure |
DMS bridge |
-25 hPa ...
+25 hPa |
0.1 or 1 Pa
set by user |
± 2 Pa
or 5 % rel. |
0.1 Pa |
10 s |
| Diff. Pressure |
DMS bridge |
-25 hPa ...
+25 hPa |
0.1 or 1 Pa
set by user |
± 2 Pa
or 1 % rel. |
0.1 Pa |
10 s |
| V - flow velocity |
Pitot tube |
1..30 m/s |
0.1 m/s |
0.5 m/s
or 2 % rel. |
1 m/s |
10 s |
| rH -relative humidity |
capacitive sensor |
5..95 % |
0.01 % |
2 % rH
or 2 % rel. |
5 % |
10 s |